We have a long experience in electrical switchgear and control gear such as Low and Medium-Voltage Switchgear (up to 24 kV), Control Relay Panel, and Low Voltage Distribution and Lighting Panels also we supplies of superior quality materials such as panels ,air-conditioning & refrigeration system equipment, compressors, etc

Detail PM710MG Power Meter PM710 - Basic Readings, THD + Min/max + RS485 PM71

Power Meter

power meter PM710 - basic readings, THD + min/max + RS485
PM710MG

Spesifikasi

Main
Range of product : PowerLogic PM700
Device short name : PM710
Product or component type : Power meter

Complementary
Power quality analysis : Total harmonic distortion
Type of measurement :
- Current
- Voltage
- Frequency
- Power factor total
- Apparent power total
- Active power total
- Reactive power total
- Apparent power per phase
- Active power per phase
- Reactive power per phase
- Energy
supply voltage :
125...250 V DC
115...415 V AC 45...65 Hz
Network frequency : 45...65 Hz
Maximum power consumption in VA : 5 VA
Display type : Backlit LCD
Display resolution : 6 lines
Sampling rate : 32 samples/cycle
Measurement current :
5 A
1 A
input type : Current 0.005...6 A (impedance <= 0.1 Ohm)
Measurement voltage :
10…480 V AC 45...65 Hz phase to phase
10…277 V AC 45...65 Hz phase to neutral
Measurement accuracy :
- Power 1 %
- Current 0.5 % 1...6 A
- Voltage 0.5 % 50...227 V
- Frequency 0.02 Hz 45...65 Hz
- Power factor 0.0034 1A to 6A and from -0.5 to +0.5
Accuracy class :
- Class 2 reactive energy conforming to IEC 62053-23
- Class 1 active energy conforming to IEC 62053-21
Communication port protocol : Modbus 19.2 kbauds
Communication port support : RS485
Data recording : Min/max of instantaneous values

Environment
Electromagnetic compatibility :
- Limits for harmonic current emissions: , conforming to IEC 61000-3-2
- Conducted and radiated emissions: , conforming to EN 55011 class B
- Electrostatic discharge immunity test: , class III, conforming to IEC 61000-4-2
- Susceptibility to electromagnetic fields: , class III, conforming to IEC 61000-4-3
- Electrical fast transient/burst immunity test: , class III, conforming to IEC 61000-4-4
- 1.2/50 µs shock waves immunity test: , class III, conforming to IEC 61000-4-5
- Conducted RF disturbances: , class III, conforming to IEC 61000-4-6
- Immunity to impulse waves: , class III, conforming to IEC 61000-4-8
- Immunity to microbreaks and voltage drops: , class III, conforming to IEC 61000-4-11
- Limitation of voltage changes, voltage fluctuations and flicker in low-voltage: , conforming to IEC 61000-3-3
mounting mode : Flush-mounted
Mounting support : Panel
Type of installation : Indoor installation
Overvoltage category : III
IP degree of protection :
- IP30 back: conforming to IEC 60529
- IP52 front face: conforming to IEC 60529
Relative humidity : 95 % at 50 °C
Pollution degree : 2
Ambient air temperature for operation : -5…50 °C
Ambient air temperature for storage : -40…85 °C
Operating altitude : 0...3000 m
Standards :
- IEC 61010-1
- UL 508
- CSA C22.2 No 14
product certifications :
- CE
- cULus
Width : 96 mm
Depth : 69 mm
Height : 96 mm
Net weight : 0.37 kg